Un greffage en vitamine E pour une membrane
aux bƩnƩfices multiples
La membrane VItabranE⢠rĆ©sulte de lāassociation des avantages reconnus de la polysulfone et des bĆ©nĆ©fices dāun anti-oxydant liposoluble : lāα tocophĆ©rol ou vitamine E.
28 %
Diminution moyenne des doses d’EPO de 28 %
31 % de rƩduction des doses de fer
24 %
Diminution moyenne des doses d’EPO de 24 %
La membrane greffĆ©e en vitamine E amĆ©liore la rĆ©ponse Ć lāEPO chez les patients dialysĆ©s Ć bas grade dāinflammation.
On behalf: VIVRE cohort and EVIA study
Poster ASN Washington 2019, JP. Cristol; M. Morena
En outre, lāhĆ©modialyseur VIE A est performant sur lāĆ©limination des moyennes molĆ©cules au-delĆ du poids molĆ©culaire de 17Ā 000 Da [9].
[1] Vitamin E-derived copolymers continueĀ the challenge to hemodialysis biomaterials.Ā
Francesco Galli.Ā World J Nephrol 2012; 1(4): 100-105
Ā
[2]Ā Evaluation of the Biocompatibility ofĀ Dialysis Membranes.Ā
Kenichi Kokubo Yoshitaka Kurihara,Ā Kozue Kobayashi Hiroshi Tsukao, Hirosuke Kobayashi.Ā Blood Purif 2015;40:293ā297
Ā
[3]Ā Vitamin EācoatedĀ polysuifone membraneĀ improved red blood cell antioxidant status inĀ hemodialysis patients.
AnneāSophie Bargnoux, Jeanā Paul Cristol, Isabelle Jaussent, Lotfi Chalabi, Pierre Bories, JeanāJacques Dion,Ā Patrick Henri, Martine Delage, Anneā Marie Dupuy, StĆ©phanie Badiou, BernardĀ Canaud, Marion Morena.
Ā J Nephrol 2013;26(3):556-63
Ā
[4]Ā Effects of vitaminĀ E coated dialyzer on oxidative stress and inflammation status in haemodialysisĀ patients : a systematic review and meta-analysis.Ā
Shi-Kun Yang, Li Xiao, Bo Xu,Ā Xiao-Xuan Xu, Fu You Liu, Li Sun.Ā Renal Failure 2014; 36(5):722-31
Ā
[5]Ā Evaluation of the Impact of a NewĀ Synthetic Vitamin E-Bonded Membrane on the Hypo-Responsiveness to theĀ Erythropoietin Therapy in Hemodialysis Patients: A Multicenter Study.
Francesco Locatelli, Simeone Andrulli, Sara Maria Viganò, Massimo Concetti, Sauro Urbini, Franca Giacchino, Roberto Broccoli, Filippo Aucella, Maria Cossu, Paolo Conti, Laura Fattori, Giorgio Punzo, Daniela Angelini, Marco Peruzzini, Salvatore Di Giulio, Marta Piroddi, Francesco Galli, Lucia Del Vecchio.
Ā Blood Purif 2017;43(4):338-345
Ā
[6]Ā A randomized controlled trial evaluating the erythropoiesis stimulating agent sparing potential of a vitamin E-bonded polysulfone dialysis membrane.
Simon W.Ā Lines, Angela M. Carter, Emma J. Dunn, Elizabeth J. Lindley, James E.Ā Tattersall, Mark J. Wright.Ā Nephrol Dial Transplant 2014, Volume 29, IssueĀ 3, Pages 649ā656
Ā
[7]Ā Evaluation of the impact of a new synthetic vitamin E-bondedĀ membrane on anemia and rHuEPO requirement in ESRD patients with centralĀ venous catheters: a pilot study.
S Mandolfo, BĀ Corradi, R Bucci, M Farina, F Pilolli, F Galli. Ā Intern Urol and Nephrol 2012, volume 44,Ā pages1493ā1500
Ā
[8]Ā Vitamin E polysulfone dialyzer improves erythropoietinĀ hyporesponsiveness in chronic kidney disease patients on dialysis with lowĀ grade inflammation.
MarionĀ Morena, Jean-Paul CristolĀ Ā Abstract ASN 2019/Hemodialysis and Frequent Dialysis
Ā
[9]Ā Randomised trial on clinical performances and biocompatibility of four high flux hemodialyzers in two mode treatments : hemodialysis vs post-dilution hemodiafiltration.
Marion Morena, Caroline Creput, Mouloud Bouzernidj, Annie Rodriguez, Lotfi Chalabi, Bruno Seigneuric, CĆ©line Lauret, Anne-Sophie Bargnoux, Anne-Marie Dupuy & Jean-Paul Cristol Scientific Reports Vol 9 – N° 18265 (2019)
Dispositif mĆ©dical destinĆ© au traitement par hĆ©modialyse et par hĆ©modiaļ¬ltration pour des patients souffrant dāinsuffisance rĆ©nale aiguĆ« ou chronique. MarquĆ© CE classe IIb par lāorganisme notifiĆ© TĆV Rheinland n°0197. FabriquĆ© par Asahi Kasei Medical, Japon, reprĆ©sentĆ©e en Europe par Asahi Kasei Medical Europe GmbH, Allemagne (importateur). DistribuĆ© en Suisse par Hemotech Switzerland GmbH. Lire attentivement les instructions et les prĆ©cautions dāemploi ļ¬gurant sur la notice ainsi que les caractĆ©ristiques, performances et informations nĆ©cessaires au bon usage du DM qui y sont mentionnĆ©es. Remboursement T2A, forfait dialyse.
Le fabricant ne fait aucune dĆ©claration ou garantie de quelque nature que ce soit, y compris, mais sans s’y limiter, en ce qui concerne la qualitĆ© marchande, l’adĆ©quation, l’utilisation Ć un usage particulier, la valeur commerciale, la qualitĆ©, la sĆ©curitĆ©, l’efficacitĆ© ou la prĆ©cision, sauf dans les cas spĆ©cifiquement dĆ©crits dans les instructions d’utilisation des produits, les brochures et le site web du fabricant.